AVENSIS/CORONA SUP (RM781E)
MANUAL TRANSAXLE (E351)
31.
(a)
(b)
32.
33.
(a)
(b)
HINT:
Wrap vinyl tape on the screwdriver to prevent damaging the
synchronizer ring.
(c)
MT0781
–
MANUAL TRANSAXLE ASSEMBLY
REMOVE INPUT AND OUTPUT SHAFTS ASSEMBLY
Leaning the output shaft to the differential side, remove
the input shaft assembly.
Lift up the differential case assembly, remove the output
shaft assembly.
REMOVE MAGNET FROM TRANSAXLE CASE
REMOVE NO.5 SYNCHRONIZER RING WITH KEY
SPRING FROM NO.3 CLUTCH HUB
Remove the No.5 synchronizer ring with the key spring
from the No.3 clutch hub.
Using a screwdriver, remove the snap ring.
Remove the synchronizer rings.