Toyota AVENSIS 2000 Supplement Manual page 625

Hide thumbs Also See for AVENSIS 2000:
Table of Contents

Advertisement

AX–28
3
1
Secondary Locking Device
AVENSIS/CORONA SUP (RM781E)
AUTOMATIC TRANSAXLE (U240E)
DISASSEMBLY
1.
(a)
(b)
(c)
2
2.
(a)
A00451
NOTICE:
Pay attention not to apply unnatural load onto O/D main
switch wire harness.
(b)
(c)
(d)
3.
4.
5.
6.
(a)
(b)
(c)
D02094
7.
Remove the 3 screws and shift lock control computer.
D09908
8.
FLOOR SHIFT ASSEMBLY (RHD)
REMOVE O/D MAIN SWITCH TERMINAL
Remove O/D main switch connector from the shift lever
plate.
Disengage the secondary locking device.
Disengage the locking lug of the terminals 2 and 4, and
pull the terminals out from the rear.
REMOVE SHIFT LEVER KNOB SUB–ASSEMBLY
Remove the 2 screws and shift lever knob sub–assembly.
Remove the Shift lever knob cover.
Remove the Shift lever button and spring.
Remove the O/D main switch.
REMOVE INDICATOR LIGHT WIRE
REMOVE BULB FROM INDICATOR LIGHT WIRE
REMOVE INDICATOR HOUSING SUB–ASSEMBLY
DISASSEMBLE INDICATOR HOUSING SUB–AS-
SEMBLY
Remove the position indicator side cover.
Remove the position indicator plate.
Remove the pattern select switch.
REMOVE SHIFT LOCK CONTROL COMPUTER
REMOVE STOPPER PIN, DETENT ROD AND SPRING
AX110–01

Hide quick links: