6 Parameter Setting and Functions

6.4.3 Output Circuit Signal Allocation

6.4.3 Output Circuit Signal Allocation

Output signal functions can be allocated to the sequence signal output circuits shown below.
In general, allocate signals according to the standard settings in the following table.
CN1
Output
Connector
Terminal
Terminal
Name
Numbers
25
SO1
26
27
SO2
28
29
SO3
30
The output signal selection parameters and their factory settings and standard settings are
shown below.
Pn50E
Output Signal Selections 1
Pn50F
Output Signal Selections 2
Pn510
Output Signal Selections 3
Select the CN1 connector terminals that will output the signals.
Pn50E.
Output
signal
Factory Setting
Symbol
Name
/COIN+
Positioning com-
pleted
/COIN-
/TGON+
Rotation detec-
tion
/TGON-
/S-RDY+
Servo ready
/S-RDY-
to Pn510.
1
SO1(CN1-25,26)
2
SO2(CN1-27,28)
3
SO3(CN1-29,30)
6-34
Standard Setting
Symbol
Name
/COIN+
Positioning com-
pleted
/COIN-
/BK+
Brake interlock
/BK-
/S-RDY+
Servo ready
/S-RDY-
Factory
Standard
Setting:
Setting:
3211
3001
Factory
Standard
Setting:
Setting:
0000
0200
Factory
Standard
Setting:
Setting:
0000
0000