Input Circuit Signal Allocation - YASKAWA MECHATROLINK Sigma 2 Series User Manual

Table of Contents

Advertisement

6 Parameter Setting and Functions

6.4.2 Input Circuit Signal Allocation

The following parameter is used to enable input signal allocations. Usually this parameter is
set to 1. Do not change this setting.
Pn50A.0
Input Signal Allocation Mode
Pn50A.0 Setting
0
Reserved
1
Enables any sequence input signal settings.
Input Signal Allocation
The following signals can be allocated.
CN1
P-OT
40 (SI0)
41 (SI1)
Determines
42 (SI2)
terminal
43 (SI3)
allocation
44 (SI4)
for input
45 (SI5)
signals.
46 (SI6)
The following table shows the parameter factory settings for input signal selections 1 to 5.
Pn50A
Input Signal Selections 1
Pn50B
Input Signal Selections 2
Pn511
Input Signal Selections 5
Select the input terminal on the CN1 connector that will be used for each input signal.
Meaning
SERVOPACK
CN1-42 is factory set for
the P-OT input signal.
Any terminal from CN1-40 to
46 can be allocated to the
P-OT signal through the
Pn50A.3 setting.
6-30
Factory
Position Control
Setting:
1
Factory
Standard
Setting:
Setting:
2881
2881
Factory
Standard
Setting:
Setting:
6583
8883
Factory
Standard
Setting:
Setting:
8888
6541