1.3

Mounting the NS115

This section describes how to mount an NS115 on the SGDH SERVOPACK.
Prepare the screws for connecting the ground wire as shown in the following table:
Mounting Type
Base Mounted
Rack Mounted
Duct Vent
By mounting an NS115, the SGDH SERVOPACK can be used in a MECHATROLINK-II sys-
tem. Use the following procedure to ensure NS115 is mounted correctly.
1. Remove the connector cover from the CN10 connector on the SERVOPACK.
SERVOPACK Models
SGDH-A3 to 02BE
SGDH-A3 to 10AE
SGDH-15 to 50AE
SGDH-05 to 30DE
SGDH-60/75AE
SGDH-A3 to 02BE-R
SGDH-A3 to 50AE-R
SGDH-05 to 30DE-R
SGDH-60/75AE-P
Note: Be sure to use spring washers or flat washers. Failure to do so may
result in the screws for connecting the ground wire protruding behind
the flange, preventing the SERVOPACK from being mounted.
YASKAWA
SERVOPACK
SGDH
MODE/SET
DATA /
CHARGE
POWER
1-5
1.3 Mounting the NS115
Screw
M3 × 10 round-head screw
(spring or flat washer)
M4 × 10 round-head screws
(spring or flat washer)
M4 × 8 round-head screw
(spring or flat washer)
M4 × 6 round-head screws
(spring or flat washer)
M4 × 8 round-head screw
(spring or flat washer)
CN10
Connector cover
Remarks
Use attached screws
1
on the NS115.
Use attached screws
on the NS115.
Use front panel fixer
screws.
Use attached screws
on the NS115.
Use front panel fixer
screws.