6 Parameter Setting and Functions

6.3.1 Sequence I/O Signals

6.3 Settings According to Host Controller

6.3.1 Sequence I/O Signals

IMPORTANT
This section describes the procedure for connecting a Σ-ΙΙ Series Servo to a host controller,
including the procedure for setting related parameters.
Sequence I/O signals are used to control SERVOPACK operation. Connect these signal ter-
minals as required.
Input Signal Connections
Connect the sequence input signals as shown below. (Standard settings)
I/O power
supply
+24V
Host controller
0 V
Provide an external input power supply; the SERVOPACK does not have an internal 24-V power sup-
ply.
• External power supply specifications for sequence input signal: 24 ± 1 VDC, 50 mA min.
Yaskawa recommends using the same external power supply as that used for output circuits. The
allowable voltage range for the 24-V sequence input circuit power supply is 11 to 25 V. Although a 12-
V power supply can be used, contact faults can easily occur for relays and other mechanical contacts
under low currents. Confirm the characteristics of relays and other mechanical contacts before using a
12-V power supply.
The function allocation for sequence input signal circuits can be changed.
Refer to 6.4.2 Input Circuit Signal Allocation for more details.
SERVOPACK
CN1
3.3kΩ
+24VIN
47
40
/DEC
41
C W - O T
42
CCW-OT
43
/EXT1
44
/EXT2
45
/EXT3
46
6-16
Photocoupler