Analog Monitor
Analog monitor and option monitor (OMN1, OMN2) can be changed with parameters
Pn003.0 and Pn003.1.
Pn003.0
Pn003.1
The option monitor (OMN1, OMN2) and analog monitor (CN5) signals that can be observed
are shown in the following table, along with the monitor signal, unit, and gain.
Settings in
Pn003.0 and
Pn003.1
0
1
2
3
4
5
6
7
8 to F
Refer to 9.5 Analog Monitor of the Σ-
INFO
information on the analog monitor.
Analog Monitor 1
Analog Monitor 2
Monitor Signal
Motor speed
Speed reference
Torque reference
Position error
Position error
Reference pulse frequency
(converted to motor speed)
Motor speed
Motor speed
Reserved monitor signals
ΙΙ
Series SGM H/SGDH User's Manual (SIEPS80000005) for
6-37
6.4 Setting Up the SERVOPACK
Factory
Position Control
Setting:
2
Factory
Position Control
Setting:
0
Analog Monitor Gain
Unit of Option Monitor
(CN5)
(OMN1, OMN2)
-1
-1
1 V/1000 min
min
-1
-1
1 V/1000 min
min
1 V/100% rated torque
%
0.05 V/1 pulse
Pulse
0.05 V/100 pulses
Pulse
-1
-1
1 V/1000 min
min
-1
-1
1 V/250 min
min
-1
-1
1 V/125 min
min
6