Virtual NIC Group Configuration

648
G8264 Command Reference for ENOS 8.4
The following table describes the Virtual NIC (vNIC) Group configuration options.  
Table 370.
vNIC Group Configuration Options
Command Syntax and Usage
vnic vnicgroup <1‐32>
Enters vNIC Group Configuration mode.
Command mode: Global Configuration
[no] enable
Enables or disables the vNIC Group.
Command mode: vNIC Group configuration
[no] failover
Enables or disables uplink failover for the vNIC Group. Uplink Failover for the 
vNIC Group will disable only the affected vNIC links on the port. Other port 
functions continue to operate normally.
The default setting is disabled.
Command mode: vNIC Group configuration
[no] member <vNIC number>
Adds or removes a vNIC to the vNIC Group. The vNIC ID is comprised of the 
port number and the vNIC number. For example: 1.1.
Command mode: vNIC Group configuration
[no] port <port number or alias>
Adds or removes the selected switch port to the vNIC Group.
Command mode: vNIC Group configuration
[no] trunk <1‐64>
Adds or removes the selected Link Aggregation Group (LAG) to the vNIC 
Group.
Command mode: vNIC Group configuration
vlan <VLAN number>
Assigns a VLAN to the vNIC Group.
Command mode: vNIC Group configuration
no vnic vnicgroup <1‐32>
Deletes the selected vNIC Group.
Command mode: Global configuration
show vnicgroup
Displays the current vNIC Group parameters.