Table 219.
VMAP Configuration Options 
Command Syntax and Usage
[no] access­control vmap <1‐128> meter enable
Enables or disables VMAP port metering. 
Command mode: Global configuration
access­control vmap <1‐128> meter maximum­burst­size <32‐4096>
Sets the VMAP port metering maximum burst size in kilobits. The following 
eight values are allowed: 32, 64, 128, 256, 512, 1024, 2048 or 4096.
Command mode: Global configuration
default access­control vmap <1‐128> meter
Resets the VMAP meter configuration to its default values.
Command mode: Global configuration
access­control vmap <1‐128> mirror port <port alias or number>
Sets the specified port as the mirror target.
Command mode: Global configuration
no access­control vmap <1‐128> mirror
Disables VMAP mirroring.
Command mode: Global configuration
access­control vmap <1‐128> packet­format ethernet
  {ethernet­type2|llc|snap}
Sets to filter the specified ethernet packet format type.
Command mode: Global configuration
access­control vmap <1‐128> packet­format ip {ipv4|ipv6}
Sets to filter the specified IP packet format type.
Command mode: Global configuration
access­control vmap <1‐128> packet­format tagging {any|none|
  |tagged}
Sets to filter the based on packet tagging. The options are:
any: Filter tagged & untagged packets
none: Filter only untagged packets
tagged: Filter only tagged packets
Command mode: Global configuration
no access­control vmap <1‐128> packet­format {ethernet|ip|
  |tagging}
Disables filtering based on the specified packet format.
Command mode: Global configuration
Chapter 4: Configuration Commands