Chapter 15 — Maintaining the Drives
3. Import the magazine into the library's entry/exit pool as described in 
Perform the Update
1. Select Configuration > DLM to display the Drives screen. 
2. Click Drive Firmware Update to launch the update wizard. The Drive 
3. Select the partition containing the drives you want to update from the 
November 2020
Importing into a Storage or Cleaning Partition on page 233. 
 If necessary, export a magazine from the entry/exit pool to 
Notes:
provide an empty chamber for the magazine containing 
firmware update tapes (see Exporting or Exchanging 
Magazines and Cartridges on page 244).
 Some backup software atomically moves tapes from entry/
exit slots into the storage partition.  If this cannot be disabled 
in the software or you cannot shutdown the software to 
prevent this, you cannot use this process.
Figure 312 Click Drive Firmware Update on the Drives
screen.
Firmware Update screen displays showing the information for the last 
partition that was viewed.
drop‐down list, then click Go. The Drive Firmware Update screen 
refreshes to show the drives assigned to the selected partition.
Figure 313 Select the partition for the drives you want to
update.
Update Using the Drive Firmware Update Wizard
User Guide—Spectra TFinity Library
489