Chapter 13 — Drive Troubleshooting
 If a cleaning partition is associated with the partition containing the 
When importing a cleaning cartridge into the partition's entry/exit pool, it must be
Important
in a regular TeraPack magazine; it cannot be in a Maintenance TeraPack magazine.
 Only a user with superuser or administrator privileges can perform a 

Run the DLM Drive Health Verification Wizard

Use the following steps to launch the DLM Drive Health Verification 
wizard.
1. Log into the library as a user with superuser or administrative 
2. If necessary, import a scratch tape and a cleaning cartridge into the 
November 2020
drive, make sure the cleaning partition contains a cleaning cartridge 
with Good (green) or Usable health. You can use MLM to determine the 
health of the cleaning cartridges currently in the cleaning partition (see 
Generate MLM Reports on page 316). If necessary, import a known 
good cleaning cartridge into the cleaning partition (see Importing into a 
Storage or Cleaning Partition on page 233).
If the partition does not use a cleaning partition, a cleaning cartridge 
with Good or Usable health must be in the partition's entry/exit pool. 
Import a known good cleaning cartridge into the entry/exit pool (see 
Importing into a Storage or Cleaning Partition on page 233). 
 Both the scratch tape and the cleaning cartridge can be 
Notes:
imported into the entry/exit pool in the same magazine.
 The test will fail if the cleaning cartridge health is not Good 
or Usable.
 The cleaning cartridge must have a barcode label.
 If the entry/exit pool contains only one chamber, both the 
cleaning cartridge and the scratch cartridge must be in the 
same magazine.
DLM Drive Health test. See Understanding User Groups and Security 
on page 103 for information about the three types of user groups and 
what types of privileges each has.
privileges.
library (see Requirements for Using the Wizard on page 430).
Run the DLM Drive Health Verification Wizard
User Guide—Spectra TFinity Library
431

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the TFinity and is the answer not in the manual?

Questions and answers

This manual is also suitable for:

Tfinity library

Table of Contents