Spectra TFinity User Manual page 203

Library
Hide thumbs Also See for TFinity:
Table of Contents

Advertisement

Chapter 6 — Configuring and Managing Partitions
Option
Enable PreScan
FullScan
QuickScan
QuickScan using
Global Spares
PostScan Triggers
November 2020
The following table describes the PreScan and PostScan options.
When selected...
Enables the PreScan feature. When enabled, PreScan replaces the 
more basic Media Auto Discovery process. See Using PreScan on 
page 306 for information about this option.
Enables the FullScan feature. When enabled by selecting one or 
more PostScan triggers, FullScan uses a Global Spare drive 
assigned to the partition to verify all of the data on each cartridge. 
See Using PostScan on page 307 for information about this option.
Note:
FullScan is only available if a Global Spare drive is 
configured for the partition.
Enables the QuickScan feature. When enabled by selecting one or 
more PostScan triggers, QuickScan uses one of the drives in the 
partition to verify the data on a single wrap, from the beginning of 
the tape (BOT) to the end of the wrap or the end of recorded data 
(EOD), whichever comes first. See Using PostScan on page 307 for 
information about this option.
QuickScan is only available if the partition uses LTO‐5 or 
Note:
later generation drives or TS11xx technology drives.
Enables the QuickScan using Global Spares feature. When 
enabled by selecting one or more PostScan triggers, QuickScan 
uses a Global Spare drive assigned to the partition to verify the 
data on a single wrap, from the beginning of the tape (BOT) to the 
end of the wrap or the end of recorded data (EOD), whichever 
comes first. See Using PostScan on page 307 for information about 
this option.
Notes:
 QuickScan using Global Spares is only available if a Global 
Spare drive is configured for the partition.
 QuickScan using Global Spares is only available if the partition 
uses LTO‐5 or later generation Fibre Channel drives or TS11xx 
technology drives.
Enables PostScan and configures one or more triggers.
 Verify After Time — Add the cartridges in the partition to the 
automatic PostScan queue after the specified number of days 
have passed since the last scan. Enter the number of days in the 
Days field.
 Verify After Write — Add a cartridge to the automatic PostScan 
queue each time data is written to it.
 Verify After Read — Add a cartridge to the automatic PostScan 
queue each time data is read from it.
Note:
Selecting any of these triggers automatically enables the 
selected PostScan option.
Enable and Configure MLM PreScan and PostScan
User Guide—Spectra TFinity Library
Default
Disabled 
(cleared)
Disabled 
(no 
PostScan 
triggers 
selected)
Disabled 
(no 
PostScan 
triggers 
selected)
Disabled 
(no 
PostScan 
triggers 
selected)
Disabled 
(cleared)
203