Chapter 9 — Configuring and Using Media Lifecycle Management
 PreScan  —   A n optional process that replaces Media Auto Discovery. If 
Discovery Process The discovery process can either be manually initiated 
by you or set to run automatically so that the library discovers the 
cartridges and adds their information to the MLM database shortly after a 
cartridge is imported into the library. The discovery process is independent 
of any storage management software.
The discovery process depends on whether the library is using Media Auto 
Discovery or PreScan. With Media Auto Discovery the library reads the 
barcode label on each new cartridge in the partition; with PreScan the 
library reads the barcode label on every cartridge in the partition. If a 
barcode is not already in the MLM database, the library loads the cartridge 
into a drive and performs either a PreScan or the basic Media Auto 
Discovery. 
 If the cartridge is MLM‐enabled, the library collects the available MLM 
 If the cartridge is not MLM‐enabled, the library collects the cartridge 
When the discovery process is complete, the drive unloads the cartridge 
and the library returns the cartridge to its original location. Each 
subsequent load/unload updates the MLM database and the cartridge 
MAM, providing ongoing tracking and reporting for the cartridge.
Manual Discovery If Media Auto Discovery is not enabled or if you 
enabled MLM when the library already contained cartridges, you can start 
the media discovery process manually to add the cartridges to the MLM 
database (see Discover Cartridges Manually on page 304).
November 2020
the PreScan feature is enabled in a partition, the PreScan process runs 
instead of the Media Auto Discovery process and operates on all of the 
media in the partition, regardless of whether it is already in the MLM 
database or not.
In addition to adding information collected from the cartridge MAM to 
the MLM database, PreScan performs a basic functionality test and 
health check on each imported cartridge (see Using PreScan on 
page 306 for more information).
information from the cartridge's MAM, including the born‐on date. If 
the cartridge was used previously, the library also collects media health 
and encryption status from the MAM. The library updates the MLM 
database to include the collected information and the name of the 
partition where it currently resides. Any updated MLM information is 
also written to the MAM in the cartridge.
barcode label information, the cartridge health information, and the 
name of the partition where the cartridge currently resides. It then adds 
this information to the MLM database.
Note:
After you enable Media Auto Discovery, importing a cartridge 
into a partition triggers the discovery process in that partition.