Chapter 15 — Maintaining the Drives
Discontinue Background Operations
You cannot update drive firmware if the library is actively running any
background operations, including Media Auto Discovery, PreScan, and
PostScan.
If you do not want to wait for a Media Auto Discovery, PreScan, or
PostScan operation to complete, you can stop the Media Auto Discovery or
PreScan operation, or pause the PostScan operation. For other background
operations, you must wait for the process to complete.
Click Stop Discovery on the Media Lifecycle Management Tools screen
Click Pause PostScan on the Media Lifecycle Management Tools screen
Discontinue Backups and Empty the Drives
Before beginning the drive firmware update process, discontinue all
backup operations and remove any cartridges from the drives.
Attempting to update the firmware while the library is busy or when the drives
Caution
contain tapes may result in the update failing, failed backup jobs, or permanent
damage to the drives. If you did not already do so, stop all backup operations and
remove all tapes from the drives you are updating. If the library has SlotIQ enabled,
run the Advanced Utilities Unload All Drives followed by Resolve SlotIQ
Virtualized Drive to Slot Moves.
Update Drives Using ITDT
1. Follow the instructions in the ITDT documentation to update the drive
2. Reset the updated drives as described in Resetting a Drive on page 402
3. After the update is complete, use your storage management software to
November 2020
to stop a Media Auto Discovery or PreScan operation (see Stop the
Discovery Process on page 306).
to pause the PostScan operation for one hour (see Pause the PostScan
Process on page 315).
If possible, use your storage management software to move any
cartridges that are currently in drives back to their storage locations.
If you cannot use your storage management software, then move
the cartridges as described in Moving Cartridges Within a Partition
on page 273.
firmware.
to restore their configuration settings.
restart any backup processes.
User Guide—Spectra TFinity Library
Update Using ITDT
478