Chapter 7 — Importing and Exporting Cartridges
6. Use the Chamber drop‐down list to select the source chamber for the
7. Click Add Move. An entry listing the move you just defined appears in
8. Repeat Step 5 on page 256 through Step 7 to add more moves to the
9. Continue with Start the Moves on page 262.
November 2020
move, then click Go to refresh the screen.
For moves to the TAP from either the entry/exit or storage pool, the
selected chamber is the source for the move. The TeraPack Case
Contents list shows the barcodes of the cartridges in the magazine in
the selected chamber.
For moves from the TAP to either the entry/exit or storage pool, the
selected chamber is the destination for the move. Use the Chamber
drop‐down list to select an empty chamber in the selected pool.
the Move Queue list.
Figure 161 Add the move to the Move Queue.
Move Queue.
Changing the selected partition or the selected TAP clears the
Notes:
move queue.
If you select the Center TAP, You can add moves from
different directions to the same move queue. When using a
bulk TAP, all moves in the queue must be either imports or
exports.
If you do not want to perform one or more of the moves in
the queue, do the following:
Select the move and click Delete to remove it from the
Move Queue list.
Click Delete All to remove all of the defined moves from
the Move Queue list.
Manually Create a Move Queue
User Guide—Spectra TFinity Library
258
Need help?
Do you have a question about the TFinity and is the answer not in the manual?
Questions and answers