Chapter 12 — Library Troubleshooting
4. Stop any PreScan or PostScan operations that are currently running (see 
5. Plug the USB device containing the MLM database backup file into a 
6. From the toolbar menu, select Maintenance > Tools. The Maintenance 
7. Select Utilities. The Utilities screen displays.
8. Click Show Advanced. The Advanced Utilities Confirmation screen 
9. Click Next. The Utilities screen refreshes to show a list of the advanced 
10. Scroll down and select Restore MLM Database from USB. The screen 
11. Use the Select a restore time stamp drop‐down list to select the 
12. Click Run Utility.
November 2020
Stop the Discovery Process on page 306 and Pause the PostScan Process 
on page 315).
USB port on the LCM or operator panel and allow time for the device to 
mount before continuing.
Tools screen displays.
displays.
utilities.
refreshes to show the details for the utility.
Figure 253 Select the Restore MLM Database from USB utility.
xlminfo<date-time>.db
containing the MLM database backup you want to use for the restore.
After a brief delay, the Utility Results screen displays, showing that the 
database was restored.
After an MLM database restore, the Discover Media button on the 
Note:
Media Lifecycle Management Tools screen (Maintenance >
MLM) may be active even if all cartridges have been discovered. 
Restore the MLM and DLM Databases
 or 
cminfo_<date-time>.zdt
User Guide—Spectra TFinity Library
file 
400

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the TFinity and is the answer not in the manual?

Questions and answers

This manual is also suitable for:

Tfinity library

Table of Contents