Chapter 9 — Configuring and Using Media Lifecycle Management
When the PreScan process is complete, the library stores the tape health 
information for the cartridge in the MLM database. It also writes the MLM 
data to the cartridge MAM. When the drive ejects the cartridge, the library 
returns it to its original slot.
Requirements for Use When using PreScan, make sure that you consider 
the following requirements:
Consideration
Drive Firmware
Updating MLM
Data on MAM
Drive Availability
Auto Drive Clean
Restrictions
Cleaning Partitions
U
P
S
SING
OST
This section provides detailed information about how PostScan operates, 
as well as prerequisites for using PostScan and performing manual 
PostScan operations.
PostScan is enabled and configured for each individual partition. PostScan does not
Important
operate until the PostScan option is selected and one or more triggers are specified for
the partition (see
November 2020
Requirement
 LTO‐4: requires 97F9 or later firmware.
 LTO‐5: requires B170 or later firmware.
 LTO‐6 and later: supported with any firmware.
 TS11xx technology: supported with any firmware.
Updating the cartridge MAM requires the cartridge to be write‐enabled.
Important:
If a cartridge is write-protected when it is inserted into a drive, the
information about the cartridge is added to the MLM database, but the library
cannot update the MLM information on the cartridge's MAM.
The media discovery process loads the cartridges in the partition into the drives 
assigned to that partition. While in use for PreScan, host moves to the drives 
being used are delayed until the PreScan operation completes. Spectra Logic 
highly recommends that you perform the manual media discovery process 
when your storage management software is not accessing the library and the 
library is idle.
Auto drive clean operations do not start while PreScan is running on any 
partition that is associated with the cleaning partition. If a drive requires 
cleaning, wait until the PreScan operation is complete and then manually clean 
the drive.
The PreScan feature cannot be enabled for a cleaning partition and does not 
affect the operation of cleaning cartridges.
CAN
Enable and Configure MLM PreScan and PostScan on page 201
Note:
PostScan cannot be configured for use in the same partition as 
Spectra SKLM or KMIP encryption key management.
Stop the Discovery Process
User Guide—Spectra TFinity Library
).
307