Overview During normal operations, you typically use your storage 
management software to move cartridges from one location to another 
within the library. However, you may occasionally need to create and 
process a move queue to direct the library to move cartridges manually. 
This can be done using the library's BlueScale interface to locate and move 
individual cartridges (for example, to move a cleaning cartridge stored in 
the storage partition to a drive if you are not using the Auto Drive Clean 
option) or by uploading a series of moves to a storage partition using a 
specially formatted ASCII text file. Use the instructions in one of the 
following sections to manually direct cartridge moves.
User Privilege Requirements The user privilege requirements when 
moving cartridges in a storage partition depend on how the library is being 
accessed. See Specify the Partition Users on page 208 for information about 
assigning users to a partition.
 Any user with operator privileges who is assigned to the partition and 
 Only a user with superuser or administrator privileges can move 
Usage Requirements Uploading a move queue file requires either a 
remote connection to the library using the BlueScale web interface (RLC) or 
a USB device connected to the LCM or operator panel.

Move Cartridges Using the BlueScale Inventory Screen

The library uses a move queue to direct tape cartridge moves. The move 
queue lists one or more source/destination pairs, with each pair 
representing a single move operation. 
Manually Create the Move Queue Use the following steps to create the 
move queue using the BlueScale Inventory screen.
1.
2. Display the cartridge inventory for the desired partition location (see 
November 2020
W
ITHIN A
Move Cartridges Using the BlueScale Inventory Screen
Move Cartridges Using an ASCII Move File on page 278
all users with superuser or administrator privileges can move 
cartridges within the partition using the BlueScale interface on the 
operator panel.
cartridges within the partition using the BlueScale web interface (RLC) 
or upload a move queue file.
Log into the library as a user with the required privileges (see User 
Privilege Requirements above).
View the Cartridge Inventory for a Location on page 267 for more 
details).
a. From the toolbar menu, select General > Inventory. 
b. Select the partition for which you want to view the inventory from 
the Partition drop‐down list, then click Go.
Move Cartridges Using the BlueScale Inventory Screen
P
ARTITION
User Guide—Spectra TFinity Library