Spectra TFinity User Manual page 161

Library
Hide thumbs Also See for TFinity:
Table of Contents

Advertisement

Chapter 5 — Operating the Library
3. Read the message(s), and follow any recommended steps.
4. When you are finished reading the messages and have completed the 
Use Syslog
The BlueScale Syslog feature sends all system messages logged by the 
library to a previously configured Syslog server. Syslog is a standard for 
forwarding log messages over an Internet Protocol (IP) computer network. 
It provides separation of the software that generates log messages from the 
system that stores the messages.
Each system message the library sends to the Syslog server contains the 
original system message posted by the library and the remedy information 
associated with the system message.
See Syslog Server IP Address on page 116 for information about entering 
the IP address of the Syslog server. Entering a valid IP address enables the 
Syslog feature.
When enabled, the BlueScale Syslog feature automatically sends all system 
messages posted by the library to a single, previously configured Syslog 
server. The library transmits the messages to the Syslog server using the 
format: 
<severity level>BlueScale_<library name>[PP]:(<message number>)
<message text>
where: 
Variable
severity level
library name
November 2020
Note:
Some error messages are followed by a series of errors that 
provide additional information. To understand the sequence of 
events, scroll back to view the first error message that was 
produced, then read the others for clarification.
If you need assistance, contact Spectra Logic Technical Support (see 
Contacting Spectra Logic on page 7).
appropriate actions, you can select and delete individual messages or 
you can delete all of the messages.
Definition
Indicates the severity the library assigned to the message. This severity 
corresponds to the syslog priorities as follows:
This library system message severity...
Informational
Warning
Error
Fatal Error
The name of the library, if configured. If the library name is not configured, this 
value is set to "UnknownLibrary."
Refer to Library Name on page 113 for information about setting the library name.
Check and Respond to Messages
Corresponds to this Syslog priority...
6 (Informational)
4 (Warning)
3 (Error)
2 (Critical)
User Guide—Spectra TFinity Library