No.
(Addr.
Name
Hex)
U1-29
(07AA) Software No. (PWM)
U1-75
Time-Hour/Minute
(0851)
U1-76
Date – Year
(0852)
U1-77
Date – Month/Day
(0853)
U1-78
Date – Week Day
(0854)
U1-79
(0B9A)
PI Feedback Back-up
<5>
U1-80
Geothermal
(0B9B)
Temperature Input
U1-81
Differential PI
(0B9C)
Feedback
<6>
U1-82
Two Motor Time to
(0B9D)
Alternate
<6>
U1-83
Flow Rate
(0B9E)
U1-84
Accumulation Level -
(0B9F)
Millions
U1-85
Accumulation Level -
(0BA0)
Thousands
U1-86
Accumulation Level -
(0BA1)
Ones
U1-87
Accumulation Level -
(0BA2)
Decimal
U1-88
Total Volume
(N/A)
Accumulated
<6>
U1-89
Delta Volume
(N/A)
Accumulated
<6>
U1-90
Pump Setpoint
(0BA5)
U1-91
(0BA6)
Pump Feedback
<7>
YASKAWA TOEP YAIP1W 01F YASKAWA AC Drive - iQpump1000 User Manual
LCD Display
PWM ID
CPU 3 SW Number
Note:
Time Hr Min HHMM Displays the current time (Hours and Minutes).
Displays the current year.
Date Year
Displays the current date (Month and Date).
Date Mo Day MMDD
Displays the current day of the week.
0: Sunday
1: Monday
2: Tuesday
Date Week
3: Wednesday
4: Thursday
5: Friday
6: Saturday
Displays the PI Feedback Back-up signal (H3-oo = 24) used
PI Fdbk Backup
when the primary PI Feedback (H3-oo = B) is lost.
Displays the geothermal temperature input after the gain and
bias have been applied. This temperature is used by the
Geothermal Temp
Geothermal Function to determine the proper frequency at
which to run the drive.
This monitor is internally limited to -999.9 °F to +999.9 °F.
Diff PI Feedback
Differential Feedback signal (H3-oo = 28).
2Motor Alt Time
Time remaining before making a motor switch.
Displays the flow rate based on the pulse input frequency or the
analog voltage (flow rate input) and parameters P6-01 and
Flow Rate
P6-04.
A 2-second first order filter will be applied to this monitor.
Displays the recorded volume from the flow meter (pulse input
Volume * 1000000
or analog voltage).
Total volume is calculated as follows:
Volume * 1000
Total Volume = (U1-84 * 1000000) + (U1-85 * 1000) + U1-86
+ U1-87
Volume * 1
Volume * 0.0001
Total Vol (gal) or Total
Displays the total volume.
Vol (A-F)
Delta Vol (gal) or Total
Displays the delta volume: Total Volume (U1-88/U1-84 to
Vol (A-F)
U1-87) - Starting Delta Volume (P6-36 to P6-39).
Displays the PID Setpoint.
Pump Setpoint
Displays the PID Feedback.
Pump Feedback
Description
This monitor is only displayed in models 4A0930
and 4A1200.
B.16 U: Monitors
Analog
Unit
Output Level
No signal output
available
No signal output
available
No signal output
available
No signal output
available
No signal output
available
No signal output
dep. on
available
P1-02
No signal output
0.1 °F
available
No signal output
dep. on
available
P1-02
No signal output
min
available
dep. on
P6-04
Full scale: P6-01
and
P6-22
No signal output
dep. on
available
P6-16
dep. on
Full scale: N/A
P6-16
dep. on
Full scale: N/A
P6-16
No signal output
dep. on
available
P1-02
No signal output
dep. on
available
P1-02
B