B.8 H Parameters: Multi-Function Terminals
No.
(Addr.
Name
Hex)
H3-13
Analog Input Filter
(041B)
Time Constant
H3-14
Analog Input Terminal
(041C)
Enable Selection
H3-16
Terminal A1 Offset
(02F0)
H3-17
Terminal A2 Offset
(02F1)
H3-18
Terminal A3 Offset
(02F2)
H3-oo
Function
Setting
0
Frequency bias
1
Frequency gain
Auxiliary frequency
2
reference 1
Auxiliary frequency
3
reference 2
4
Output voltage bias
5
Accel/decel time gain
DC Injection Braking
6
current
Overtorque/
7
undertorque
detection level
Stall Prevention level
8
during run
Output frequency lower
9
limit level
B
PID feedback
C
PID setpoint
D
Frequency bias
Motor Temperature
E
(PTC Input)
F
Through mode
10
Forward torque limit
11
Reverse torque limit
384
LCD Display
Sets a primary delay filter time constant for terminals A1, A2,
A1/A2 Filter T
and A3. Used for noise filtering.
Determines which analog input terminals will be enabled when
A1/A2/A3 Sel
a digital input programmed for "Analog input enable"
1: A1 Available
(H1-oo = C) is activated.
2: A2 Available
1: Terminal A1 only
3: A1/A2 Available
2: Terminal A2 only
4: A3 Available
3: Terminals A1 and A2 only
5: A1/A3 Available
4: Terminal A3 only
6: A2/A3 Available
5: Terminals A1 and A3
7: All Available
6: Terminals A2 and A3
7: All terminals enabled
Adds an offset when the analog signal to terminal A1 is at 0 V. Default: 0
TerminalA1Offset
Adds an offset when the analog signal to terminal A2 is at 0 V. Default: 0
TerminalA2Offset
Adds an offset when the analog signal to terminal A3 is at 0 V. Default: 0
TerminalA3Offset
H3 Multi-Function Analog Input Settings
LCD Display
Freq Ref Bias
10 V = E1-04 (maximum output frequency)
0 to 10 V signal allows a setting of 0 to 100%. -10 to 0 V signal allows a setting
Freq Ref Gain
of -100 to 0%.
10 V = E1-04 (maximum output frequency)
Aux Reference1
10 V = E1-04 (maximum output frequency)
Aux Reference2
V/f
V/f
Voltage Bias
10 V = E1-05 (motor rated voltage)
Acc/DecTime Change 10 V = 100%
10 V = Drive rated current
DC Brake Current
10 V = Drive rated current (V/f)
Torque Det Level
V/f
V/f
Stall Prev Level
10 V = Drive rated current
10 V = E1-04 (maximum output frequency)
Ref Lower Limit
PID Feedback1
10 V = 100%
PID Set Point
10 V = 100%
Freq Ref Bias 2
10 V = E1-04 (maximum output frequency)
10 V = 100%
Motor PTC
Note:
Select this setting when using the terminal in a pass-through mode. The terminal
Not Used
does not trigger a drive function but can be used as digital input for the controller
the drive is connected to.
OLV
OLV
OLV
OLV
Fwd Torque Limit
10 V = Motor rated torque
OLV
OLV
OLV
OLV
Rev Torque Limit
10 V = Motor rated torque
Description
Description
A 12 kΩ resistor must be connected between terminals A1, A2, or
A3 and V+ for PTC functionality.
YASKAWA TOEP YAIP1W 01F YASKAWA AC Drive - iQpump1000 User Manual
Values
Page
Default: 0.03 s
Min.: 0.00
Max.: 2.00
Default: 7
Range: 1 to 7
Min.: -500
Max.: 500
Min.: -500
Max.: 500
Min.: -500
Max.: 500
Page