YASKAWA iQpump1000 User Manual page 39

Ac drive intelligent pump controller
Hide thumbs Also See for iQpump1000:
Table of Contents

Advertisement

n
Vertical Suspension of Drive Models 2A0360, 2A0415, and 4A0250 to 4A1200
Models 2A0360, 2A0415, and 4A0250 to 4A0675
When vertical suspension of the drive is required in an enclosure panel, change the orientation of the eye bolts for these models
by turning the eye bolts counterclockwise 90 degrees.
Models 4A0930 and 4A1200
When suspending models 4A0930 or 4A1200 with wires, follow the procedure described below.
WARNING! Crush Hazard. Use an adequate length of wire to ensure a 50° or wider suspension angle as illustrated in
maximum allowable load of the eye bolts cannot be guaranteed when the drive is suspended with the wires at angles less than 50°. Failure
to comply may result in serious injury or death from falling equipment.
1.
Remove the four eye bolts from the drive side panels and fix them securely on the top panel.
2.
Pass wire through the holes of all four eye bolts.
A – Eye bolt
B – Wires
YASKAWA TOEP YAIP1W 01F YASKAWA AC Drive - iQpump1000 User Manual
Figure 2.6 Adjusting Angle of Eye Bolts
Figure 2.7 Eye Bolt Repositioning
B
A
C – Suspending angle: 50° or greater
Figure 2.8 Suspension Wire Angle Example
2.1 Mechanical Installation
Eye bolt
C
Figure
2.8. The
2
39

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents