n
Flange Type Heat Loss Data
Drive Model
2A0110
Drive Model
4A0058
n
Flange Type Panel Cutout Dimensions for External Heatsink Mounting
YASKAWA TOEP YAIP1W 01F YASKAWA AC Drive - iQpump1000 User Manual
2.2 Flange Type Enclosure (NEMA 12 Backside) Dimensions & Heat Loss
Table 2.18 Models 2A0110 and 4A0058
Voltage
ND (Fc = 2 kHz)
Class
Internal
External
200
286
Voltage
Input Type
Class
Internal
400
6-Pulse
215
NOTES:
1. CUTOUT TOLERANCES:
+/- 0.02 in. [0.5 mm]
2. EXPOSED HEATSINK DEPTH
D=3.82 in. [97 mm] MINUS PANEL THICKNESS
3. MINIMUM RECOMMENDED PANEL
THICKNESS: 12 GA
Figure 2.28 Models 2A0110 and 4A0058
Heat Loss (W)
Total
Internal
719
1005
211
Heat Loss (W)
ND (Fc = 2 kHz)
External
Total
471
686
(8)-1/4 in. [M6]
THREADED HOLES
CUTOUT
Unit: in. [mm]
HD (Fc = 8 kHz)
External
Total
510
721
HD (Fc = 8 kHz)
Internal
External
Total
170
349
519
Wt. kg (lb)
23 (50.6)
Wt. kg (lb)
23 (50.6)
2