B.7 F: Options
No.
(Addr.
Name
Hex)
F6-26
MECHATROLINK
(03CA)
bUS Errors Detected
F6-30
PROFIBUS-DP Node
(03CB)
Address
F6-31
PROFIBUS-DP Clear
(03CC)
Mode Selection
F6-32
PROFIBUS-DP Data
(03CD)
Format Selection
F6-45
BACnet Node Address BAC Node Address
(02FB)
F6-46
BACnet Baud Rate
(02FC)
F6-47
Rx to Tx Wait Time
(02FD)
F6-48
BACnet Device Objcet
(02FE)
ID 0
F6-49
BACnet Device Objcet
(02FF)
ID 1
F6-50
DeviceNet MAC
(03C1)
Address
F6-51
DeviceNet
(03C2)
Communication Speed
F6-52
DeviceNet PCA Setting PCA Selection
(03C3)
F6-53
DeviceNet PPA Setting PPA Selection
(03C4)
F6-54
DeviceNet Idle Mode
(03C5)
Fault Detection
F6-55
DeviceNet Baud Rate
(03C6)
Monitor
F6-56
DeviceNet Speed
(03D7)
Scaling
F6-57
DeviceNet Current
(03D8)
Scaling
370
LCD Display
Num of SI-T BUS
Sets the number of option communication errors (bUS).
Sets the node address.
PB Node Address
PB Clear Select
0: Resets drive operation with a Clear mode command.
0: Reset to Zero
1: Maintains the previous operation state when Clear mode
1: Hold Prev Value
command is given.
PB Map Select
0: PPO Type
0: PPO Type
1: Conventional
1: Conventional
Sets the node address.
BAC Baud Rate
0: 1200 bps
0: 1200 bps
1: 2400 bps
1: 2400 bps
2: 4800 bps
2: 4800 bps
3: 9600 bps
3: 9600 bps
4: 19.2 kbps
4: 19.2 kbps
5: 38.4 kbps
5: 38.4 kbps
6: 57.6 kbps
6: 57.6 kbps
7: 76.8 kbps
7: 76.8 kbps
8: 115.2 kbps
8: 115.2 kbps
Rx to Tx Wait Time
Rx to Tx Wait T
BACnet device object ID
BAC Dev Obj Id 0
BACnet device object ID
BAC Dev Obj Id 1
Selects the drive MAC address.
DN MAC Address
DN Baud Rate
0: 125 kbps
0: 125 kbps
1: 250 kbps
1: 250 kbps
2: 500 kbps
2: 500 kbps
3: Adjustable from network
3: Set from Network
4: Detect automatically
4: Auto Detect
Sets the format of the data set from the DeviceNet master to the
drive.
Sets the format of the data set from the drive to the DeviceNet
master.
DN Idle Flt Det
0: Enabled
0: Stop
1: Disabled, no fault detection
1: Ignore
DN BAUD RATE
Verifies the baud rate running on the network.
MEM
0: 125 kbps
0: 125 kbps
1: 250 kbps
1: 250 kbps
2: 500 kbps
2: 500 kbps
Sets the scaling factor for the speed monitor in DeviceNet.
Speed Scale
Sets the scaling factor for the output current monitor in
Current Scale
DeviceNet.
Description
YASKAWA TOEP YAIP1W 01F YASKAWA AC Drive - iQpump1000 User Manual
Values
Page
Default: 2
Min.: 2
Max.: 10
Default: 0
Min.: 0
Max.: 125
Default: 0
Range: 0, 1
Default: 0
Range: 0, 1
Default: 1
Min.: 0
Max.: 127
Default: 3
Range: 0 to 8
Default: 5 ms
Min.: 5
Max.: 65
Default: 0
Min.: 0
Max.: FFFF
Default: 0
Min.: 0
Max.: 3F
Default: 64
Min.: 0
Max.: 64
Default: 4
Range: 0 to 4
Default: 21
Min.: 0
Max.: 255
Default: 71
Min.: 0
Max.: 255
Default: 0
Range: 0, 1
Default: 0
Range: 0 to 2
Default: 0
Min.: -15
Max.: 15
Default: 0
Min.: -15
Max.: 15