B.8 H Parameters: Multi-Function Terminals
No.
(Addr.
Name
Hex)
H1-28
(02DE) External Fault 8 Delay
Time
H1-31
(09E1)
Terminal S1 On-Delay
Time
<2>
H1-32
Terminal S2 On-Delay
(09E2)
Time
<2>
H1-33
(09E3)
Terminal S3 On-Delay
Time
<2>
H1-34
(09E4)
Terminal S4 On-Delay
Time
<2>
H1-35
(09E5)
Terminal S5 On-Delay
Time
<2>
H1-36
(09E6)
Terminal S6 On-Delay
Time
<2>
H1-37
(09E7)
Terminal S7 On-Delay
Time
<2>
H1-38
(09E8)
Terminal S8 On-Delay
Time
<2>
H1-41
(09EB)
Terminal S1 Off-Delay
Time
<2>
H1-42
(09EC)
Terminal S2 Off-Delay
Time
<2>
H1-43
(09ED)
Terminal S3 Off-Delay
Time
<2>
H1-44
(09EE)
Terminal S4 Off-Delay
Time
<2>
H1-45
(09EF)
Terminal S5 Off-Delay
Time
<2>
374
LCD Display
Sets the amount of time delay applied to the EF8 fault.
(20 ≤ H1-08 ≤ 2F)
EF8 Delay Time
Sets the length of time that Terminal S1 must be closed before
Term S1 On-Delay
the drive performs the programmed function.
Sets the length of time that Terminal S2 must be closed before
Term S2 On-Delay
the drive performs the programmed function.
Sets the length of time that Terminal S3 must be closed before
Term S3 On-Delay
the drive performs the programmed function.
Sets the length of time that Terminal S4 must be closed before
Term S4 On-Delay
the drive performs the programmed function.
Sets the length of time that Terminal S5 must be closed before
Term S5 On-Delay
the drive performs the programmed function.
Sets the length of time that Terminal S6 must be closed before
Term S6 On-Delay
the drive performs the programmed function.
Sets the length of time that Terminal S7 must be closed before
Term S7 On-Delay
the drive performs the programmed function.
Sets the length of time that Terminal S8 must be closed before
Term S8 On-Delay
the drive performs the programmed function.
Sets the length of time needed for Terminal S1 to be open before
Term S1 OffDelay
the drive removes the programmed function.
Sets the length of time needed for Terminal S2 to be open before
Term S2 OffDelay
the drive removes the programmed function.
Sets the length of time needed for Terminal S3 to be open before
Term S3 OffDelay
the drive removes the programmed function.
Sets the length of time needed for Terminal S4 to be open before
Term S4 OffDelay
the drive removes the programmed function.
Sets the length of time needed for Terminal S5 to be open before
Term S5 OffDelay
the drive removes the programmed function.
Description
YASKAWA TOEP YAIP1W 01F YASKAWA AC Drive - iQpump1000 User Manual
Values
Page
Default: 0.00 s
Min.: 0.00
Max.: 300.00
Default: 0.0 s
Min.: 0.0
Max.: 3000.0
<3>
Default: 0.0 s
Min.: 0.0
Max.: 3000.0
<3>
Default: 0.0 s
Min.: 0.0
Max.: 3000.0
<3>
Default: 0.0 s
Min.: 0.0
Max.: 3000.0
<3>
Default: 0.0 s
Min.: 0.0
Max.: 3000.0
<3>
Default: 0.0 s
Min.: 0.0
Max.: 3000.0
<3>
Default: 0.0 s
Min.: 0.0
Max.: 3000.0
<3>
Default: 0.0 s
Min.: 0.0
Max.: 3000.0
<3>
Default: 0.0 s
Min.: 0.0
Max.: 3000.0
<3>
Default: 0.0 s
Min.: 0.0
Max.: 3000.0
<3>
Default: 0.0 s
Min.: 0.0
Max.: 3000.0
<3>
Default: 0.0 s
Min.: 0.0
Max.: 3000.0
<3>
Default: 0.0 s
Min.: 0.0
Max.: 3000.0
<3>

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents