YASKAWA iQpump1000 User Manual page 252

Ac drive intelligent pump controller
Hide thumbs Also See for iQpump1000:
Table of Contents

Advertisement

5.2 Fault Detection
HOA Keypad Display
Communication data error occurred due to
noise
The option card is damaged
The option card is not properly connected
to the drive
HOA Keypad Display
CE
Cause
Faulty communications wiring or an
existing short circuit
Communication data error occurred due to
noise
HOA Keypad Display
CPF11 to CPF14
CPF16 to CPF19
Cause
There is a self-diagnostic error in the
control circuit
Connector on the operator is damaged
HOA Keypad Display
CPF02
Cause
Control circuit is damaged
HOA Keypad Display
CPF03
Cause
There is a connection error
252
• Check the various options available to minimize the effects of noise.
• Counteract noise in the control circuit, main circuit, and ground wiring.
• Ensure that other equipment such as switches or relays do not cause noise. Use surge absorbers if
necessary.
• Use only recommended cables or other shielded line. Ground the shield on the controller side or the drive
input power side.
• Separate all communication wiring from drive power lines. Install an EMC noise filter to the drive power
supply input.
Replace the option card if there are no problems with the wiring and the error continues to occur.
• The connector pins on the option card do not line up properly with the connector pins on the drive.
• Reinstall the option card.
MEMOBUS/Modbus Communication Error
Control data was not received for the CE detection time set to H5-09.
• Check for faulty wiring.
• Correct the wiring.
• Check for disconnected cables and short circuits and repair as needed.
• Check the various options available to minimize the effects of noise.
• Counteract noise in the control circuit, main circuit, and ground wiring.
• Use only recommended cables or other shielded line. Ground the shield on the controller side or the drive
input power side.
• Ensure that other equipment such as switches or relays do not cause noise. Use surge suppressors if
required.
• Separate all communication wiring from drive power lines. Install an EMC noise filter to the drive power
supply input.
Control Circuit Error
• Cycle power to the drive.
• If the problem continues, replace the control board or the entire drive. Contact Yaskawa or a Yaskawa
representative for instructions on replacing the control board.
Replace the operator.
A/D Conversion Error
An A/D conversion error or control circuit error occurred.
• Cycle power to the drive.
• If the problem continues, replace the control board or the entire drive. Contact Yaskawa or a Yaskawa
representative for instructions on replacing the control board.
Control Board Connection Error
Connection error between the control board and the drive
• Turn off the power and check the connection between the control board and the drive.
• If the problem continues, replace the control board or the entire drive. Contact Yaskawa or a Yaskawa
representative for instructions on replacing the control board.
Fault Name
Fault Name
Possible Solution
Fault Name
Possible Solution
Fault Name
Possible Solution
Fault Name
Possible Solution
YASKAWA TOEP YAIP1W 01F YASKAWA AC Drive - iQpump1000 User Manual

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents