YASKAWA iQpump1000 User Manual page 267

Ac drive intelligent pump controller
Hide thumbs Also See for iQpump1000:
Table of Contents

Advertisement

HOA Keypad Display
The motor thermistor is not connected
properly.
<1> Detected in models 4A0930 and 4A1200.
HOA Keypad Display
TIE
Cause
An error has occurred in the Real-Clock
Time function of the HOA keypad.
HOA Keypad Display
TIM
Cause
The Real-Time Clock for the HOA keypad
is not set in parameter o4-17 and a feature
that requires RTC information is enabled.
• The drive is a new drive, first power-up
condition
• o4-17 was set to 2, Reset, by the user,
manually clearing the Real-Time Clock
data.
The user did not set the Real Time Clock
when prompted following power-up.
The HOA keypad battery is low or the
battery has been replaced.
An error has occurred in the Real-Time
Clock function of the HOA keypad.
HOA Keypad Display
TLGI Geothermal Input
Cause
The input signal level has dropped below
3 mA or risen above 21 mA when the drive
was running and b1-01 = 5, H3-0o = 21
(Geothermal Input), H3-0o = 2
(4 to 20 mA), and Q2-09 = 2 (Fault).
The drive was running while b1-01 = 5,
H3-0o≠ 21 (Geothermal Temp), and
Q2-09 = 2 (Fault).
HOA Keypad Display
UL3
Cause
Parameter settings are not appropriate for
the load
There is a fault on the machine side
HOA Keypad Display
UL4
Cause
Parameter settings are not appropriate for
the load
There is a fault on the machine side
YASKAWA TOEP YAIP1W 01F YASKAWA AC Drive - iQpump1000 User Manual
Check the thermistor wiring.
Time Interval Error
Replace the HOA keypad. For instructions on replacing the HOA keypad, contact Yaskawa or your nearest
sales representative.
Time Not Set
Possible Solution
Set o4-17 to 1 to set the time for the HOA keypad.
The drive will display the "Clock Not Set" alarm when the Real time Clock is not set. Additionally, at power
up, if the "TIM" condition is present, the drive will automatically switch to the time setting screen (o4-17 =
1) for 30 seconds to prompt the user to set the Real-Time Clock.
Cycle power to the drive and set the Real Time Clock within 30 seconds of power-up, or set the clock
manually via parameter o4-17.
Replace the HOA keypad battery and set the Real-Time Clock.
Replace the digital operator. For instructions on replacing the HOA keypad, contact Yaskawa or your nearest
sales representative.
Temperature Lost Geothermal Input
The geothermal input is not present.
Confirm that the device connected to the analog input terminal is installed and working properly.
Assign one of the analog inputs to "Geothermal Temperature", H3-0o = 21.
Undertorque Detection 1
The current has fallen below the minimum value set for torque detection (L6-02) for longer than the allowable
time (L6-03).
Check the settings of parameters L6-02 and L6-03.
Check the load for any problems.
Undertorque Detection 2
The current has fallen below the minimum value set for torque detection (L6-05) for longer than the allowable
time (L6-06).
Check L6-05 and L6-06 settings
Check the load for any problems.
Fault Name
Fault Name
Possible Solution
Fault Name
Fault Name
Possible Solutions
Fault Name
Possible Solution
Fault Name
Possible Solution
5.2 Fault Detection
5