H1-oo
Function
Setting
Select Secondary PI
AD
Parameters
Emergency Override
AF
Forward Run
Emergency Override
B0
Reverse Run
<1> Available in drive software versions PRG: 8552 and later. Not available in drive models 4A0930 and 4A1200.
u
H2: Multi-Function Digital Outputs
No.
(Addr.
Name
Hex)
Terminal M1-M2
H2-01
function selection
(040B)
(relay)
Terminal M3-M4
H2-02
function selection
(040C)
(relay)
H2-03
Terminal MD-ME-MF
(040D)
Function Selection
H2-06
Watt Hour Output Unit
(0437)
Selection
H2-31
Terminal M1/M2 On-
(09D1)
Delay Time M1/M2 On M1/M2 On Delay
<2>
H2-32
Terminal M3/M4 On-
(09D2)
Delay Time
<2>
H2-33
Terminal MD/ME/MF
(09D3)
On-Delay Time
<2>
H2-41
Terminal M1/M2 Off-
(09D9)
Delay Time
<2>
H2-42
Terminal M3/M4 Off-
(09DA)
Delay Time
<2>
H2-43
Terminal MD/ME/MF
(09DB)
Off-Delay Time
<2>
<1> Default is F in drive software versions PRG: 8551 and earlier.
<2> Available in drive software versions PRG: 8554 and later. Not available in drive models 4A0930 and 4A1200.
H2-oo
Function
Setting
0
During run
1
Zero speed
YASKAWA TOEP YAIP1W 01F YASKAWA AC Drive - iQpump1000 User Manual
H1 Multi-Function Digital Input Selections
LCD Display
Closed: Uses the secondary PI controller Proportional and Integral adjustments
(S3-06 and S3-07) instead of the primary PI controller Proportional and Integral
adjustments (b5-02 and b5-03). Only valid when S3-01 = 0 (secondary PI
Select PI2 Parms
controller disabled).
Note:
EmergOverrideFWD Closed: Run the drive forward using the speed set in S6-02.
Closed: Run the drive in reverse using the speed set in S6-02.
EmergOverrideREV
LCD Display
Refer to H2 Multi-Function Digital Output Settings on pages
M1-M2 Func Sel
224
to
224
M3/M4 Func Sel
MD/ME/MF Func Sel
Outputs a 200 ms pulse signal when the watt-hour counter
increases by the units selected.
0: 0.1 kWh units
Pwr Mon Unit Sel
1: 1 kWh units
2: 10 kWh units
3: 100 kWh units
4: 1000 kWh units
Sets the amount of time needed for the programmed function
(H2-01) to be active before M1/M2 closes.
Sets the amount of time needed for the programmed function
M3/M4 On Delay
(H2-02) to be active before M3/M4 closes.
Sets the amount of time needed for the programmed function
MD/ME/MF OnDelay
(H2-03) to be active before MD/MF closes, or ME/MF opens.
Sets the amount of time needed for the programmed function
M1/M2 Off Delay
(H2-01) to be inactive before M1/M2 opens.
Sets the amount of time needed for the programmed function
M3/M4 Off Delay
(H2-02) to be inactive before M3/M4 opens.
Sets the amount of time needed for the programmed function
MD/ME/MF Off Dly
(H2-03) to be inactive before MD/MF opens, or ME/MF closes.
H2 Multi-Function Digital Output Settings
LCD Display
During RUN 1
Closed: A Run command is active or voltage is output.
Open: Output frequency is above the minimum output frequency set in E1-09.
Zero Speed
Closed: Output frequency is below the minimum output frequency set in E1-09.
B.8 H Parameters: Multi-Function Terminals
Description
This multi-function input has no effect on the secondary PI
controller. It is only used for the primary PI controller (b5-oo).
Description
for descriptions of setting values.
Description
Page
Values
Page
Default: 37
223
Range: 0 to 1AC
<1>
Default: 42
223
Range: 0 to 1AC
Default: E
223
Range: 0 to 1AC
Default: 0
Range: 0 to 4
Default: 0.0 s
Range: 0.0 to
3000.0
Default: 0.0 s
Range: 0.0 to
3000.0
Default: 0.0 s
Range: 0.0 to
3000.0
Default: 0.0 s
Range: 0.0 to
3000.0
Default: 0.0 s
Range: 0.0 to
3000.0
Default: 0.0 s
Range: 0.0 to
3000.0
Page
B
379