Drive
Model
Figure
W
4A0208A
450
<1>
(17.72)
(27.76)
4A0250A
500
<1>
(19.69)
(31.50)
1
4A0296A
500
<1>
(19.69)
(31.50)
4A0362A
500
<1>
(19.69)
(31.50)
500
4A0414A
2
(19.69)
(37.40)
670
1140
4A0515A
(26.38)
(44.88)
3
670
1140
4A0675A
(26.38)
(44.88)
1250
1380
4A0930A
4
(49.21)
(54.33)
1250
1380
4A1200A
4
(49.21)
(54.33)
<1> Customers may convert these models to IP20/NEMA 1, UL Type 1 enclosures using an IP20/NEMA 1, UL Type 1 Kit.
UL Type 1 Kit Selection on page 52
Drive
Model
Figure
W
5A0125A
450
<1>
(17.72)
(27.76)
5A0145A
450
<1>
(17.72)
(27.76)
1
5A0192A
500
<1>
(19.69)
(31.50)
5A0242A
500
<1>
(19.69)
(31.50)
<1> Customers may convert these models to IP20/NEMA 1, UL Type 1 enclosures using an IP20/NEMA 1, UL Type 1 Kit.
UL Type 1 Kit Selection on page 52
YASKAWA TOEP YAIP1W 01F YASKAWA AC Drive - iQpump1000 User Manual
Table 2.9 Dimensions for IP00/Open Type Enclosure: 400 V Class
H
D
W1
W2
705
330
325
10
(12.99)
(12.80)
(0.39)
800
350
370
10
(13.78)
(14.57)
(0.39)
800
350
370
10
(13.78)
(14.57)
(0.39)
800
350
370
10
(13.78)
(14.57)
(0.39)
950
370
370
8
(14.57)
(14.57)
(0.31)
370
440
610
(14.57)
(17.32)
(0.24)
370
440
610
(14.57)
(17.32)
(0.24)
370
1110
6
(14.57)
(43.70)
(0.24)
370
1110
6
(14.57)
(43.70)
(0.24)
to select the appropriate kit.
Table 2.10 Dimensions for IP00/Open Type Enclosure: 600 V Class
H
D
W1
W2
705
330
325
10
(12.99)
(12.80)
(0.39)
705
330
325
10
(12.99)
(12.80)
(0.39)
800
350
370
10
(13.78)
(14.57)
(0.39)
800
350
370
10
(13.78)
(14.57)
(0.39)
to select the appropriate kit.
Dimensions (in)
W3
W4
H1
H2
680
12
(26.77)
(0.49)
773
13
(30.43)
(0.51)
73
13
(30.43)
(0.51)
73
13
(30.43)
(0.51)
923
13
(36.34)
(0.51)
220
1110
15
(8.66)
(43.70)
(0.59)
220
1110
15
(8.66)
(43.70)
(0.59)
330
440
1345
15
(13.00)
(17.32)
(52.95)
(0.59)
330
440
1345
15
(13.00)
(17.32)
(52.95)
(0.59)
Dimensions (in)
W3
W4
H1
H2
680
12
(26.77)
(0.49)
680
12
(26.77)
(0.49)
73
13
(30.43)
(0.51)
73
13
(30.43)
(0.51)
2.1 Mechanical Installation
D1
t1
t2
d
130
3
3
M10
(5.12)
(0.13)
(0.13)
130
5
5
M12
(5.12)
(0.18)
(0.18)
130
5
5
M12
(5.12)
(0.18)
(0.18)
130
5
5
M12
(5.12)
(0.18)
(0.18)
135
5
5
M12
(5.31
(0.18)
(0.18)
150
5
5
M12
(5.91)
(0.18)
(0.18)
150
5
5
M12
(5.91)
(0.18)
(0.18)
150
4.6
4.6
M12
(5.91)
(0.18)
(0.18)
150
4.6
4.6
M12
(5.91)
(0.18)
(0.18)
Refer to IP20/NEMA 1,
D1
t1
t2
d
130
3
3
M10
(5.12)
(0.13)
(0.13)
130
3
3
M10
(5.12)
(0.13)
(0.13)
130
5
5
M12
(5.12)
(0.18)
(0.18)
130
5
5
M12
(5.12)
(0.18)
(0.18)
Refer to IP20/NEMA 1,
Wt. (lb)
79
(174.2)
96
(211.6)
102
(224.9)
107
(235.9)
125
(275.6)
216
(476.2)
221
(487.2)
545
(1201.5)
555
(1223.6)
Wt.
(lb)
79
(174.2)
79
(174.2)
107
(235.9)
107
(235.9)
2