YASKAWA iQpump1000 User Manual page 492

Ac drive intelligent pump controller
Hide thumbs Also See for iQpump1000:
Table of Contents

Advertisement

D.1 European Standards
Three-Phase 200 V / 400 V Class
A – Make sure the ground wire is
B – Grounding surface (remove any
C – Metal plate
D – Enclosure panel
E – Drive
F – Motor cable (braided shield cable,
Figure D.4 EMC Filter and Drive Installation for CE Compliance (Three-Phase 200 V / 400 V Class)
492
K
J
grounded
paint or sealant)
max. 10 m)
A
B
I
H
G
G – Motor
H – Cable shield ground
I – Cable clamp
J – Ground plate (scrape off any
visible paint)
K – EMC noise filter
YASKAWA TOEP YAIP1W 01F YASKAWA AC Drive - iQpump1000 User Manual
D
C
E
B
F

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents