YASKAWA iQpump1000 User Manual page 399

Ac drive intelligent pump controller
Hide thumbs Also See for iQpump1000:
Table of Contents

Advertisement

No.
(Addr.
Name
Hex)
o1-10
User-Set Display Units
(0520)
Maximum Value
o1-11
User-Set Display Units
(0521)
Decimal Display
o1-12
(0522)
Home Help Text
Frequency Reference
o1-13
and Frequency Related
(3105)
Monitor Custom Units 1
Frequency Reference
o1-14
and Frequency Related
(3106)
Monitor Custom Units 2
Frequency Reference
o1-15
and Frequency Related
(3107)
Monitor Custom Units 3
<1> Default setting is determined by parameter A1-02, Control Method Selection.
u
o2: HOA Keypad Keypad Functions
No.
(Addr.
Name
Hex)
o2-02
STOP Key Function
(0506)
Selection
o2-03
User Parameter Default
(0507)
Value
o2-04
Drive Model Selection
(508)
Frequency Reference
o2-05
Setting Method
(0509)
Selection
Operation Selection
o2-06
when Digital Operator is
(050A)
Disconnected
Motor Direction at
o2-07
Power Up when Using
(0527)
Operator
o2-19
Parameter Set Selection
(061F)
YASKAWA TOEP YAIP1W 01F YASKAWA AC Drive - iQpump1000 User Manual
LCD Display
These settings define the display values when o1-03 is set to 3.
o1-10 sets the display value that is equal to the maximum output
UserDisp Scaling
frequency.
o1-11 sets the position of the decimal position.
UserDisp Dec Sel
Switches the top line of the Home Screen from the Drive Status
Top Help on Home
to defined Help messages.
0: Disabled
0: Disabled
1: Enabled
1: Enabled
Sets the first character of the customer-specified unit display
Fref Cust Unit 1
when o1-03 is set to 3 and o1-09 is set to 24.
Sets the second character of the customer-specified unit display
Fref Cust Unit 2
when o1-03 is set to 3 and o1-09 is set to 24.
Sets the third character of the customer-specified unit display
Fref Cust Unit 3
when o1-03 is set to 3 and o1-09 is set to 24.
LCD Display
Oper STOP Key
0: Disabled. STOP key is disabled in REMOTE operation.
0: Disabled
1: Enabled. STOP key is always enabled.
1: Enabled
0: No change.
User Default Sel
1: Set defaults. Saves parameter settings as default values for a
0: No Change
User Initialization.
1: Save User Init
2: Clear all. Clears the default settings that have been saved for
2: Clear User Init
a User Initialization.
Enter the drive model. Setting required only if installing a new
Inverter Model #
control board.
Oper Ref Method
0: ENTER key must be pressed to enter a frequency reference.
0: Disabled
1: ENTER key is not required. The frequency reference can be
1: Enabled
adjusted using the up and down arrow keys only.
Oper Discon Det
0: The drive continues operating if the digital operator is
0: Disabled
disconnected.
1: Enabled
1: An oPr fault is triggered and the motor coasts to stop.
This parameter requires assigning drive operation to the digital
For/RevSel@PwrUp
operator.
0: Forward
0: Forward
1: Reverse
1: Reverse
Selects whether parameter settings can be changed during a DC
bus undervoltage condition. To be used with 24 V Power Supply
option (PS-A10L, PS-A10H) revision B or later.
0: Disabled
1: Enabled
ParameterSet Sel
0: Disabled
Note:
1: Enabled
B.11 o: Operator-Related Settings
Description
Description
1. This parameter is not available in models
4A0930 and 4A1200.
2. Enabling this function may trigger a CPF06
fault when used with a 24 V Power Supply
option revision earlier than B, as the
parameter changes might not occur correctly.
Values
Page
<1>
Default:
Range: 1 to
60000
<1>
Default:
Range: 0 to 3
Default: 1
Range: 0, 1
Default: 41
Range: 20 to 7A
Default: 41
Range: 20 to 7A
Default: 41
Range: 20 to 7A
Values
Page
Default: 1
Range: 0, 1
Default: 0
Range: 0 to 2
Default:
Determined by
drive capacity
Default: 0
Range: 0, 1
Default: 1
Range: 0, 1
Default: 0
Range: 0, 1
Default: 0
Range: 0, 1
B
399

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents