B.14 S: Special Application
u
S1: Dynamic Noise Control Function
No.
(Addr.
Name
Hex)
Dynamic Audible Noise
S1-01
Control Function
(3200)
Selection
S1-02
Voltage Reduction Rate Volt Reduce Amt
(3201)
S1-03
Voltage Restoration
(3202)
Level
S1-04
Voltage Restoration
(3203)
Complete Level
Voltage Restoration
S1-05
Sensitivity Time
(3204)
Constant
S1-06
Voltage Restoration
Time Constant at Impact Impact Load Time
(3205)
u
S2: Programmable Run Timers
No.
(Addr.
Name
Hex)
S2-01
Sequence Timer 1 Start
(3206)
Time
S2-02
Sequence Timer 1 Stop
(3207)
Time
S2-03
Sequence Timer 1 Day
(3208)
Selection
S2-04
Sequence Timer 1
(3209)
Selection
YASKAWA TOEP YAIP1W 01F YASKAWA AC Drive - iQpump1000 User Manual
LCD Display
Dyn Noise Ctrl
V/f
V/f
0: Disabled
0: Disabled
1: Enabled
1: Enabled
V/f
V/f
Sets the rate at which the output voltage will be reduced as a
percentage of the V/f pattern when operating with no load.
V/f
V/f
V Reduce On Lvl
Sets the level when the drive should start restoring the voltage
as a percentage of the drive rated torque.
V/f
V/f
Sets the level at which voltage restoration for the V/f pattern is
V Reduce Off Lvl
complete as a percentage of the drive rated torque. If the output
torque rises above the value of S1-04, then the voltage will be
controlled in a manner specified by the V/f pattern setting.
V/f
V/f
Sets the level of sensitivity of the output torque and LPF time
Sensitivity Time
constants for the voltage reduction rate. The level of sensitivity
can be adjusted in accordance with the load response.
V/f
V/f
Sets the voltage restoration time constant if an impact load is
added.
LCD Display
Sets the start time for timer 1.
Note:
Tmr 1 Start Time
Sets the stop time for timer 1.
Note:
Tmr 1 Stop Time
Tmr 1 Day Sel
Sets the days for which sequence timer 1 is active.
0: Timer disabled
0: Timer disabled
1: Daily
1: Daily
2: Mon - Fri
2: Mon - Fri
3: Sat - Sun
3: Sat - Sun
4: Monday
4: Monday
5: Tuesday
5: Tuesday
6: Wednesday
6: Wednesday
7: Thursday
7: Thursday
8: Friday
8: Friday
9: Saturday
9: Saturday
10: Sunday
10: Sunday
Sets the action that occurs when sequence timers 1 is active.
Tmr 1 Seq Sel
0: Digital output only
0: Digital Out Only
1: Run
1: Run
2: Run - PI disable
2: Run - PI Disable
3: AllowAlternation
3: Allow Alternation
Description
Description
The value must be set less than or equal to S2-02
in drive software versions PRG: 8551 and earlier.
The value must be set greater than or equal to
S2-01 in drive software versions PRG: 8551 and
earlier.
<2>
B.14 S: Special Application
Values
Page
Default: 0
Range: 0, 1
Default: 50.0%
Min.: 50.0
Max.: 100.0
Default: 20.0%
Min.: 0.0
Max.: 90.0
Default: 50.0%
Min.: S1-03 +
10.0
Max.: 100.0
Default: 1.000 s
Min.: 0.000
Max.: 3.000
Default: 0.050 s
Min.: 0.000
Max.: 1.000
Values
Page
Default:
<3>
12:00AM
Min.: 12:00AM
Max.: 11:59PM
<1>
Default:
<3>
12:00AM
Min.: 12:00AM
Max.: 11:59PM
<1>
Default: 0
Range: 0 to 10
Default: 0
Range: 0 to 3
245
B
431