Setting
7
Accel/decel time selection 1
8
Baseblock command (N.O.)
9
Baseblock command (N.C.)
A
Accel/decel ramp hold
B
Drive overheat alarm (oH2)
C
Analog terminal input selection
F
Through mode
10
Up command
11
Down command
12
Forward Jog
13
Reverse Jog
14
Fault reset
15
Fast Stop (N.O.)
17
Fast Stop (N.C.)
18
Timer function input
19
PID disable
1A
Accel/decel time selection 2
1B
Program lockout
1E
Reference sample hold
20 to 2F Ext. pump fault
30
PID integral reset
31
PID integral hold
Multi-Step Speed
32
Reference 4
34
PID soft starter cancel
35
PID input level selection
Forward run command
40
(2-Wire sequence)
Reverse run command
41
(2-Wire sequence)
Run command
42
(2-Wire sequence 2)
FWD/REV command
43
(2-Wire sequence 2)
47
Node setup
51
Sequence Timer Disable
52
Sequence Timer Cancel
60
DC Injection Braking command
External Speed Search
61
command 1
<1> Available in drive software versions PRG: 8552 and later.
Not available in drive models 4A0930 and 4A1200.
n
H2-01 to H2-03: Terminal M1-M2, M3-M4, and MD-ME-MF Function Selection
The drive has three multi-function output terminals.
H2-02, and H2-03.
No.
H2-01
Terminal M1-M2 Function Selection (relay)
H2-02
Terminal M3-M4 Function Selection (relay)
H2-03
Terminal MD-ME-MF Function Selection (relay)
<1> Default is F: Through Mode in drive software versions PRG: 8551 and earlier.
YASKAWA TOEP YAIP1W 01F YASKAWA AC Drive - iQpump1000 User Manual
Function
Table 4.22
Parameter Name
4.7 Basic iQpump Setup and Application Preset Parameters
Page
Setting
–
External Speed Search
62
command 2
–
63
Field weakening
–
65
KEB Ride-Thru 1 (N.C.)
–
66
KEB Ride-Thru 1 (N.O.)
–
67
Communications test mode
–
68
High Slip Braking (HSB)
–
6A
Drive enable
–
73
Low City Press
–
75
Up 2 command
–
76
Down 2 command
–
7A
KEB Ride-Thru 2 (N.C.)
–
7B
KEB Ride-Thru 2 (N.O.)
–
80
HAND Mode
–
81
HAND Mode 2
–
<1>
PI Switch to Aux
82
–
83
Alternate Multi-Setpoint (Q1-02)
–
84
Alternate Multi-Setpoint (Q1-03)
–
85
Alternate Multi-Setpoint (Q1-04)
–
88
Volute-Thermostat Normally Open
–
89
Volute-Thermostat Normally Closed
–
8C
Disable Pre-Charge
–
8D
Multi Setpoint 1
–
8E
Multi Setpoint 2
–
8F
Low Water Level
–
90
High Water Level
92
Reset Accum
–
95
Remove Drive Disable
–
A8
Secondary PI Disable (N.O.)
A9
Secondary PI Disable (N.C.)
–
AA
Secondary PI Inverse Operation
AB
Secondary PI Integral Reset
–
AC
Secondary PI Integral Hold
–
AD
Select Secondary PI Parameters
–
AF
Emergency Override Forward Run
–
B0
Emergency Override Reverse Run
–
–
lists the functions available for these terminals using H2-01,
Function
Setting Range
0 to 192
37: During Frequency Output
0 to 192
42: Pressure Reached
0 to 192
Page
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
4
Default
<1>
E: Fault
223