YASKAWA iQpump1000 User Manual page 400

Ac drive intelligent pump controller
Hide thumbs Also See for iQpump1000:
Table of Contents

Advertisement

B.11 o: Operator-Related Settings
No.
(Addr.
Name
Hex)
o2-30
(1230)
Monitor Position Save
u
o3: Copy Function
No.
(Addr.
Name
Hex)
o3-01
Copy Function
(0515)
Selection
o3-02
Copy Allowed Selection
(0516)
u
o4: Maintenance Monitor Settings
No.
(Addr.
Name
Hex)
o4-01
Cumulative Operation
(050B)
Time Setting
o4-02
Cumulative Operation
(050C)
Time Selection
o4-03
Cooling Fan Operation
(050E)
Time Setting
o4-05
Capacitor Maintenance
(051D)
Setting
DC Bus Pre-Charge
o4-07
Relay Maintenance
(0523)
Setting
o4-09
IGBT Maintenance
(0525)
Setting
o4-11
U2, U3 Initialization
(0510)
o4-12
kWh Monitor
(0512)
Initialization
Number of Run
o4-13
Commands Counter
(0528)
Initialization
o4-17
Set/Reset Real-Time
(3100)
Clock
400
LCD Display
Saves the monitor position and Home Screen quick monitor
selection.
Mon Pos Save
Setting this parameter to 0 and then entering the Monitor Menu
0: Disabled
will jump the selection to the monitor number instead of the
1: Enabled
group number.
0: Disabled
1: Enabled
LCD Display
0: No action
Copy Function Sel
1: Read parameters from the drive, saving them onto the digital
0: COPY SELECT
operator.
1: INV→OP READ
2: Copy parameters from the digital operator, writing them to
2: OP→INV WRITE
the drive.
3: OP←→INV
3: Verify parameter settings on the drive to check if they match
VERIFY
the data saved on the operator.
Read Allowable
0: Read operation prohibited
0: Disabled
1: Read operation allowed
1: Enabled
LCD Display
Sets the value for the cumulative operation time of the drive in
DrvElapsTimeCnt
units of 10 h.
ElapsTimeCntSet
0: Logs power-on time
0: Power-On Time
1: Logs operation time when the drive output is active (output
1: Running Time
operation time).
Sets the value of the fan operation time monitor U4-03 in units
FanElapsTimeCn
of 10 h.
Sets the value of the Maintenance Monitor for the capacitors.
BusCap Maint Set
See U4-05 to check when the capacitors may need to be
replaced.
Sets the value of the Maintenance Monitor for the soft charge
ChrgCircMaintSet
bypass relay. See U4-06 to check when the bypass relay may
need to be replaced.
Sets the value of the Maintenance Monitor for the IGBTs. See
IGBT Maint Set
U4-07 for IGBT replacement times.
0: U2-oo and U3-oo monitor data is not reset when the drive
Fault Data Init
is initialized (A1-03).
0: Disabled
1: U2-oo and U3-oo monitor data is reset when the drive is
1: Enabled
initialized (A1-03).
0: U4-10 and U4-11 monitor data is not reset when the drive is
kWh Monitor Init
initialized (A1-03).
0: No Reset
1: U4-10 and U4-11 monitor data is reset when the drive is
1: Reset
initialized (A1-03).
0: Number of Run commands counter is not reset when the drive
Run Counter Init
is initialized (A1-03).
0: No Reset
1: Number of Run commands counter is reset when the drive is
1: Reset
initialized (A1-03).
Date/Time Config
Sets the current date and time for the Real-Time Clock.
0: — —
0: - -
1: Set
1: Set
2: Reset
2: Reset
Description
Description
Description
YASKAWA TOEP YAIP1W 01F YASKAWA AC Drive - iQpump1000 User Manual
Values
Page
Default: 0
Range: 0, 1
Values
Page
Default: 0
Range: 0 to 3
Default: 1
Range: 0, 1
Values
Page
Default: 0
Min.: 0
Max.: 9999
Default: 1
Range: 0, 1
Default: 0
Min.: 0
Max.: 9999
Default: 0%
Min.: 0
Max.: 150
Default: 0%
Min.: 0
Max.: 150
Default: 0%
Min.: 0
Max.: 150
Default: 0
Range: 0, 1
Default: 0
Range: 0, 1
Default: 0
Range: 0, 1
Default: 0
136