4 Repair
4.5.1 Replacing the balancing device
Continued
3
4
5
6
Continues on next page
238
Action
DANGER
Turn off all:
electric power supply
hydraulic pressure supply
air pressure supply
to the robot, before entering the robot working
area.
Remove the protection hood in the upper end
of the balancing device.
Insert two screws, M12x50 in the holes to
neutralize the spring force. Screw in the screws
until they have proper contact with the cylinder
inside.
The length of the cylinder is now locked and
the balancing device is unloaded. It should now
be possible to easily rotate the balancing
device.
Attach a lifting accessories to the balancing
device.
Use the hole in the lifting ear.
© Copyright 2006-2020 ABB. All rights reserved.
Note
xx1000001112
Product manual - IRB 660
3HAC025755-001 Revision: W