4 Repair
4.4.8 Replacing the complete lower arm
Continued
Equipment, etc.
Standard toolkit
Other tools and procedures
may be required. See refer-
ences to these procedures in
the step-by-step instructions
below.
Circuit diagram
Deciding calibration routine
Decide which calibration routine to be used, based on the information in the table.
Depending on which routine is chosen, action might be required prior to beginning
the repair work of the robot, see the table.
1
Removal, lower arm
The procedure below details how to remove the lower arm.
1
Continues on next page
222
Action
Decide which calibration routine to use for
calibrating the robot.
Reference calibration. External cable
packages (DressPack) and tools can
stay fitted on the robot.
Fine calibration. All external cable
packages (DressPack) and tools
must be removed from the robot.
If the robot is to be calibrated with refer-
ence calibration:
Find previous reference values for the axis
or create new reference values. These val-
ues are to be used after the repair proced-
ure is completed, for calibration of the ro-
bot.
If no previous reference values exist, and
no new reference values can be created,
then reference calibration is not possible.
If the robot is to be calibrated with fine
calibration:
Remove all external cable packages
(DressPack) and tools from the robot.
Action
Decide which calibration routine to use, and take
actions accordingly prior to beginning the repair
procedure.
© Copyright 2006-2020 ABB. All rights reserved.
Art.no.
-
Note
Follow the instructions given in the refer-
ence calibration routine on the FlexPendant
to create reference values.
Creating new values requires possibility to
move the robot.
Read more about reference calibration for
Axis Calibration in
routine on page
Read more about reference calibration for
Pendulum Calibration in Operating manu-
al - Calibration Pendulum.
Note
Note
Content is defined in section
Standard tools on page
347.
These procedures include refer-
ences to the tools required.
See chapter
Circuit diagrams on
page
355.
Reference calibration
316.
Product manual - IRB 660
3HAC025755-001 Revision: W