Verification Test Logs - Quantum Scalar i6000 Installation Manual

Tape library
Hide thumbs Also See for Scalar i6000:
Table of Contents

Advertisement

Verification Test Logs

Each verification test produces a test log that details all information and results from the individual tests and
subtests. In addition, the log includes information to help you understand the test results and to help resolve
any problems encountered. To view a test log, click Reports on the Verification Tests dialog box to display
the report window, and then click the Text tab.
You can view results for the five most recent tests. Click Reports, and then click the test results you want
to view.
This log file is appended with data as each test finishes. You can repeat the test if any problems are found
and fixed. If the Verification Tests dialog box was not closed during the retesting, all results are contained
in one log file.
To save the information that the test generates, click Send. If you are using the remote LMC client, you can
choose to save the log to your hard drive. If you choose to save directly to your hard drive, the report listing
and test log are combined into one text file.
Figure 35
shows an example of a test log. It provides the following information:
The test output is from the library alignment test.
The test title is always shown between rows of equal signs.
A brief guide for understanding coordinates and offsets used in the test results is provided near the
beginning of the log.
The X-axis and Y-axis limits applied by this test are shown. MARGINAL output is placed between
parentheses, and FAILED output is placed between brackets; for example, (30) and [45].
The results of the subtest are displayed between dashed lines.
Coordinates are represented as A (aisle), F (frame), R (rack), S (section), C (column), and R (row).
All location values are in 0.1 mm.
All results that you should review are identified with four arrows (>>>>) in the column to the left of
the detailed results.
At the end of every test, summary results of every subtest are given. The overall test result is
displayed between asterisk lines, and a summary of subtest results follows.
313 to determine the meaning of the results.
Scalar i6000 Installation Guide
SeeTable 11
on page
323

Advertisement

Table of Contents
loading

This manual is also suitable for:

Scalar i2000

Table of Contents