Mechanical Locks
The access and service doors can only be opened with a key. The key should be kept by an authorized
person at your company. Access to the interior of the library is both a data integrity and a safety issue.
Door Interlock Switches
Door interlock switches detect when the access door has been opened and automatically remove power
from the picker.
DOOR INTERLOCK SWITCHES ARE PROVIDED FOR YOUR SAFETY.
WARNING
YOU SHOULD NOT INTERFERE WITH THEIR NORMAL OPERATION.
Power Button on the Library's Indicator Panel
Switching off the Power button on the indicator panel, located on the front of the library, removes power
from the electronics, which causes the picker to stop immediately. This button also removes power from the
drives.
THIS POWER BUTTON FUNCTIONS AS A POWER INTERRUPT ONLY.
WARNING
TO COMPLETELY REMOVE ALL POWER BEFORE SERVICING OR IN
AN EMERGENCY, TURN OFF THE CIRCUIT BREAKER ON THE
POWER DISTRIBUTION UNIT, AND THEN DISCONNECT THE POWER
CORD FROM THE ELECTRICAL SOURCE.
Physically Accessing the Library
The library is completely enclosed in a housing that serves as a guard, separating the danger area of the
library from the normal working area. You can access the internal components of the library through the
access and service doors only. When the library is powered on, the interlock on the access door is active.
MOVEMENTS OF MECHANICAL PARTS IN THE LIBRARY CAN CAUSE
WARNING
SERIOUS INJURY OR DEATH. ACCESS TO INTERNAL LIBRARY
COMPONENTS IS RESTRICTED TO AUTHORIZED PERSONNEL. DO
NOT ENTER THE LIBRARY UNLESS YOU ARE AUTHORIZED BY
YOUR COMPANY AND TRAINED ON HOW TO ENTER THE LIBRARY
SAFELY.
WHEN DRIVE SLED POSITIONS ARE EMPTY, DRIVE COVER PLATES
WARNING
MUST BE INSTALLED AND IN PLACE AT ALL TIMES TO PREVENT
ACCESS INTO THE EMPTY DRIVE SLED POSITIONS.