Quantum Scalar i6000 Installation Manual page 214

Tape library
Hide thumbs Also See for Scalar i6000:
Table of Contents

Advertisement

4
The Datapath Conditioning dialog box appears, showing all the I/O blades found in the library. Each
blade is identified by name and by geographic location.
5
Click a blade to highlight it and then click Configure.
The Datapath Conditioning Setting dialog box appears.
6
In the Level area, choose the appropriate level. The default level is Interface Test. To enable data path
monitoring tickets, set the level to Device Datapath Test.
The following table describes the functionality for each data path monitoring level.
Level Name
Interface Test
Device
Datapath Test
7
In the Enter new Interval text box, type the amount of time that should elapse between automatic
monitoring checks. The interval can range from 1 to 2,880 minutes (48 hours). The default interval is 60
minutes.
202
Functionality Description
Performs tests to verify that Fibre Channel controllers on I/O blade are
responsive to commands.
Everything from Interface Test level, in addition to performing a device inquiry on
each target device.
Configuring the Library