Table 7
shows an example of how the return media identifier behavior works depending on which
setting you choose: Disabled, Prefix, Suffix, and Pass Through. The bold, underlined portion
represents the media identifier.
Table 8
Return Media Identifier Behavior Example
Actual LTO-1 Barcode Label
Behavior
Disabled
Prefix
Suffix
Pass Through
Note
For more information on how media policies in the library work, see the library Scalar i6000 User's
Guide.
For Automatic Drive Cleaning, click either Enable or Disable. This setting is enabled by default.
Enabling automatic drive cleaning allows the library to initiate drive cleaning each time a drive
requests a cleaning operation. For automatic drive cleaning to function, you must first configure
drive cleaning for the library. For more information about configuring drive cleaning, see
Configuring Drive Cleaning
Note
7
Select Next to proceed.
8
In the Choose Resource Allocation Mode dialog box, select either Simple or Expert.
9
Select Next to proceed.
To continue in Simple mode, see
To continue in Expert mode, see
Scalar i6000 Installation Guide
ABC123L1
Volume serial number returned to Host
ABC123
L1ABC123
ABC123L1
ABC123L1
Once a media volume serial number has been reported to a host, changing
the Return Media Identifier setting may cause the host to not recognize
media within the library.
on page 214.
Automatic drive cleaning should be enabled for partitions only if the host
application does not support the coordination of drive cleaning. If drive
cleaning functionality is enabled on the host application, do not enable
automatic drive cleaning for any partitions in the library.
Performing Simple Partition Resource Allocation
Performing Expert Partition Resource Allocation
on page 188.
on page 190.
187

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Scalar i6000 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

This manual is also suitable for:

Scalar i2000

Table of Contents

Save PDF