Interpreting LBX Terminator LEDs
The LBX terminator has two versions. Version 01 has four LEDs and Version 03 has six LEDs. For more
information, see
LBX Board and Terminator
LBX Terminator Version 01 LEDs
The LBX terminator has four green LEDs that indicate the presence of modules in the library.
shows the locations of the LEDs.
The terminator must be located in the LBX of the last expansion module. The LED status should reflect the
physical installed module count of the system.
Figure 48
Locations of LBX Terminator LEDs (Version 01)
4
3
2
1
Table 27
Explanations of LBX Terminator LED States (Version 01)
LED On/Off Combinations
1
2
3
Off
Off
Off
On
Off
Off
On
On
Off
On
On
On
On
On
On
On
Off
On
On
On
Off
On
Off
On
On
Off
Off
362
on page 345.
Table 27
describes how to interpret LED activity on the LBX terminator.
4
Off
Robotics are disabled, the access door is open, or the LBX
terminator is misaligned.
Off
The library has one control module and no expansion modules.
Off
The library has one control module and one expansion module.
Off
The library has one control module and two expansion modules.
On
The library has one control module and three expansion modules.
On
The library has one control module and four expansion modules.
On
The library has one control module and five expansion modules.
Off
The library has one control module and six expansion modules.
On
The library has one control module and seven expansion modules.
Explanation
Interpreting LED Codes
Figure 48
Need help?