Get/Put Test
The Get/Put test performs the following tasks:
•
Performs a Get/Put of a scratch tape in the top and bottom slots of each magazine that supports
the scratch tape's media
•
Performs a Get/Put of existing media if no scratch tape is found or if the top or bottom is occupied
•
Moves a scratch tape to one row in each frame to test cross-frame alignment
•
Uses a scratch tape to perform a Get/Put in each compatible drive
Picker Assembly Test
The picker assembly test performs the following tasks:
•
Performs pivot left and right check
•
Performs reach and retract five times
•
If the LMC gets its side done, performs a Get/Put of the selected cell
•
Scans the control module serial number to make sure the scanner is reading properly
I/E Station Assembly Test
The I/E station assembly test performs the following tasks:
•
Locks and unlocks I/E station
•
Calibrates each I/E station and check offsets collected
•
Checks each magazine's fiducial in the I/E station
•
Performs Get/Put tests on all the I/E station cells
Scanner Fiducial Test
The scanner fiducial test performs the following tasks:
•
Scans and checks each magazine fiducial
•
Scans and checks each drive sled fiducial
•
Tests the calibration sensor
•
Calibrates and checks repeatability, up to three times for marginal and failed calibration targets
Library Inventory
This inventory list provides the following statistical information:
•
Frame card serial numbers
•
Power supply serial numbers
•
Number of cartridges in the library
•
Controller serial number and firmware information for the following:
•
Management control blade
•
Control management blade
•
Robotic control unit or RCU
•