Manually Bulk Loading Cartridges

This section provides instructions for bulk loading cartridges into the library.
To ensure the proper operation of tape cartridges, pickers, and drives, make
Note
sure your hands are dirt- and grease-free before handling tape cartridges.
Clean the sides of all tape cartridges with a clean, dry paper towel or cloth
before installing them in the library.
Do not bulk load cartridges into a library that will have more than one
CAUTION
partition because there is a risk the cartridges will not be accessible
by a specific partition.
Also, it is possible to insert cartridges into unlicensed slots when
they are installed manually.
Figure 22
Cartridge Insertion Into Magazine
top of cartridge
front of cartridge
Bulk loading of cartridges must be done with caution. When bulk loading cartridges make certain:
All cartridges have a valid barcode label.
The barcode side is facing out of the slot.
The cartridge is completely seated in the slot. The accessor assembly motion can be impeded if the
cartridge is not completely seated within the slot.
The media is not inserted in the slot upside down (see
The media is not dropped while loading it into the library.
142
Figure 22
).
Installing Cartridges
magazine