# start of the Level Equation Set
SPECS
# Spec - Declaration
VCC
[V] # supply voltage
VIL
[V] # low level input voltage
VIH
[V] # high level input voltage
VOL
[V] # low level output voltage
VOH
[V] # high level output voltage
DPSPINS Vcc
# DPC Pins declaration
vout
= VCC
ilimit = 1000
t_ms
= 4
offcurr= act
LEVELSET 1 "no termination"
PINS ctrl ser_in
vil= VIL
vih= VIH
PINS ser_out
vol= VOL
voh= VOH
PINS io_in
vil= VIL
vih= VIH
vol= VOL
voh= VOH
LEVELSET 2 "with termination"
PINS ctrl ser_in
vil= VIL
vih= VIH
PINS ser_out
vol= VOL
voh= VOH
vt = (VOL+VOH)/2
PINS io_in
vil= VIL
vih= VIH
vol= VOL
voh= VOH
LEVELSET 3 "active load"
Agilent 93000 SOC Series User Training Part 1, October 2004
# first Level Set without termination
# pin declaration
# second Level Set without termination
# pin declaration
# third Level Set with load current 24mA