15-1 Operating Principles
last pass value
Agilent 93000 SOC Series User Training Part 1, October 2004
Linear Search Algorithm
Default Setting (from
timing or level set) or
specified start value
(depends on TF)
Figure 262
Search Algorithms – Linear
The simplest search algorithm is linear. Here, the parameter will be
moved in fixed steps from a passing setting until a fail occurs or the
range of the search (user settings or tester capability imposed) is
exceeded.
If a functional test with the primary setting fails, no search will be
performed and you will receive a warning message. The test function
always reports the last pass value, the resolution of the result is the
same as the step size.
Advantages:
• will not miss anomalies as long as the step size is small
• setting of search range is not critical to how test is performed (and
how long it takes)
Disadvantages:
• can be very time-consuming if many steps are required to find a fail
Device Characterization - AC Tests
Step
Size
First
Fail
Search
Limit
Value
Returned
423