9-4 Equation Sets and Timing Sets
Agilent 93000 SOC Series User Training Part 1, October 2004
PINS CP
d1= 20
d2= 45
PINS mode ser_in
d1= 0
d2= 30
PINS _MR
d1= 0
d2= 15
PINS ser_out
r1= 45
PINS io_pins
d1= 2
r1= 45
TIMINGSET 2 "50MHz" # period and edge delays for a 50MHz test
period= 20
PINS CP
d1= 7
d2= 17
PINS mode
d1= 0
d2= 12
PINS ser_in
d1= 1
d2= 12
PINS _MR
d1= 0
d2= 8
Timing Setup