10-6 Sequencer Instructions
The sequencer has its own set of instructions which you can use to
control the execution of your test. You enter the instructions in the
Instr column of the Vector Setup window.
The default instruction is GENV (generate vectors) for every vector, but
the system does not display it and you do not have to enter it.
If you hold the left mouse button down in the Instr column, a menu of
the different sequencing instructions becomes available (see
Table 2
Sequencing Instructions
CTIM
CLEV
REPEAT
LOOP and LOOPEND endless loop
MATCH and MATCH-
END
STOP
#
You can include comments in the sequencer instruction column. To do
this, just enter a "#" in front of the comment text.
You can enter more than one instruction per line. To do this, separate
the instructions by ";". For example, MATCHEND; CTIM 4; CLEV 3
is a valid entry in the I
If there is not enough space in the sequencer instruction column to
display all instructions a ";" is shown instead of each instruction, which
is not displayed.
You can modify the width of the sequencer instruction column in the
Define Table Format dialog box (see
Agilent 93000 SOC Series User Training Part 1, October 2004
change the Timing Set
change the Level Set
repeat vectors
repeat until no errors
stop the sequencer (for debugging purposes only)
comment
column.
NSTR
page
10-6 Sequencer Instructions
Table
261).