Agilent Technologies 93000 SOC Series Training Manual page 424

User training part 1
Hide thumbs Also See for 93000 SOC Series:
Table of Contents

Advertisement

Device Characterization - AC Tests
Default Setting (from timing
or level set) or specified
start value (depends on TF)
424
Binary Search Algorithm
Figure 263
Search Algorithms – Binary
The next-complex search algorithm is binary. Here, the test is
performed at the defined search limits. If a pass/fail transition is indi-
cated, the search is started; otherwise a warning message occurs.
The parameter is set to halfway between the limits, and a functional
test is run again. Depending on whether this passes or fails, the param-
eter moves halfway again in the direction of expected pass/fail transi-
tion.
This is repeated until the maximum resolution of the parameter has
been reached. The test returns the pass value closest to the transition.
Advantages:
• very few steps needed, even for large search limits
• fast
• always highest possible resolution
Disadvantages:
• can miss anomalies in areas of large steps
Agilent 93000 SOC Series User Training Part 1, October 2004
15-1 Operating Principles
Fail
Point
Search
Value
Limit
Returned