12-3 Inserting Testsuites
Agilent 93000 SOC Series User Training Part 1, October 2004
.
Figure 225
Testflow Flag Page of the Testflow Editor
To debug a testsuite (analyze waveforms and results) the testsuite must
be set on hold. If a testsuite is set on hold the testsuite is executed and
the test execution stops after this testsuite. The testsuite flags allow
you to set a testsuite on hold (see figure above):
Hold
• Flag Hold
Independent of the test result test execution stops after that
testsuite.
Hold on Fail
• Flag Hold on Fail
Test execution stops after that testsuite if the testsuite fails.
If you have a testflow composed of a number of testsuites you can
control the test execution by some more flags:
Set pass
• Flag Set pass
The testsuite is executed but independent of the actual test result
the testsuite is set to pass.
Set fail
• Flag Set fail
The testsuite is executed but independent of the actual test result
the testsuite is set to fail.
Bypass
• Flag Bypass
During test execution the testsuite is bypasses.