9-3 Wavetable Setup
Physical Waveform Table
Agilent 93000 SOC Series User Training Part 1, October 2004
Wavetable Setup
The Wavetable Setup is needed to setup the wavetables in the physical
waveform table.
You access physical waveform tables from the Timing Setup Editor.
However, the information of the waveform tables is of essential impor-
tance for the vector setup.
You define the physical waveforms according to the scheme illustrated
in
Figure
Figure 113
Physical Waveform Table
Every entry of the Physical Waveform Table defines a physical wave-
form.
• You can use a maximum of 14 edges globally for all physical wave-
forms of the Physical Waveform Table. The example of
ical Waveform Table" on page 191
d2, d6, d5 and the receive edges r5, r6).
Using an edge globally for all waveforms of a wavetable means that
113.
Timing Setup
figure "Phys-
uses six edges (the drive edges d4,